| Woodfield Stoves Home | Replacement Parts | Specifications | Minimum Clearances |

Woodfield
Stove
Clearances
Single-wall stovepipe
Double-wall
stovepipe
Alcove
Maple Leaf
Birch Bark
Oak Cluster
All models
All models
A Sidewall to unit
19" (485mm)
20" (510mm)
22" (560mm)
14" (355mm)
14" (355mm)
B Backwall to unit
10" (255mm)
12" (305mm)
12" (305mm)
5" (125mm)
6" (150mm)
C Corner to wall
6" (150mm)
6" (150mm)
8" (205mm)
2" (50mm)
D Sidewall to collar
28" (710mm)
29" (735mm)
31" (790mm)
23" (585mm)
23" (585mm)
E Backwall to collar
13" (330mm)
16.5" (420mm)
16.5" (420mm)
9" (230mm)
9" (230mm)
F Wall to collar
16" (405mm)
16.5" (420mm)
19" (485mm)
11.5" (290mm)

   Min. alcove height

7' (2.13m)

   Max. alcove depth

4' (1.23m)
G Front of unit to edge of non-combustible floor pad*             18" (455mm) for all models
H Side of unit to edge of non-combustible floor pad*               8" (205mm) for all models
* A combustible floor must be protected by a non-combustible material. A non-combustible floor pad must also be under and 2" beyond each side of the chimney connector.